Neutrik powerCON TRUE1 female connector for 10-16mm cables. Rugged, locking, IP67 sealed true mains connector with breaking capacity. Certified safety.
Neutrik PowerCON TRUE1 Truecon Female Connector with Large Opening for Cables 10-16mm
The powerCON TRUE1 is a heavy-duty, sealed connector system designed to replace standard appliance couplers in situations requiring a robust locking mechanism. Its unique breaking capacity (CBC) allows for safe connection and disconnection under load or while live.
Key Features:
- Heavy-Duty and Sealed: Built for harsh and demanding environments with high impact, UV-resistant materials.
- Lockable Single-Phase Connection: Provides a secure and reliable power link.
- Extremely Robust and Reliable: Engineered for long-lasting performance in challenging conditions.
- Certified Safety: ENEC, VDE, UL, and CSA certified according to relevant IEC and UL standards.
- IP65 and IP67 Protection: Offers superior dust and water resistance when mated or with a closed cap.
- True Mains Connector with Breaking Capacity (CBC): Safe to connect and disconnect under load.
- Easy and Reliable Twist Lock System: Ensures a secure and stable connection.
- Unique NEUTRIK Locking Bushing and Strain Relief: Accommodates large cable diameters from 10 mm to 16 mm (0.39 – 0.63 inches).
- Contact resistance: ≤ 2 mΩ
- Dielectric strength: 4 kVdc / 2.8 kVac
- Insulation resistance: >0.1GΩ (after damp and heat test IEC 68-2-30)
- Number of electrical contacts: 2 + PE
- Rating Europe: 16 A / 250 V AC according to EN IEC 60320-1
- Cable O.D.: 10 - 16 mm (0.39 – 0.63 inches)
- Lifetime: > 5000 mating cycles
- Wiresize (mm²): 1.0 – 2.5mm²
- Wiresize (AWG): 14 - 12 AWG
- Contact plating: 2 μm Ag
- Locking element: Polyamide (PA 66)
- Contacts: Copper Alloy
- Insert: Polyamide (PA 66)
- Shell: Polyamide (PA 66)
- Strain relief: Polyketon
- Flammability:UL 94 V-0
- Protection class:IP 65 / 67 (mated or with closed caps)
- UV resistance: F1 rated material withstands UV exposure
- Temperature range: -30°C to +80°C according to IEC 61984, -5°C to +40°C according to IEC 60320-1